Structural Deck Inspection
Why this matters
A deck inspection identifies potential safety hazards before they cause injury. Decks built before current code (pre-2009 typically) often don't meet modern requirements; many older decks have ledger attachment failures, missing flashing, undersized fasteners, or framing decay. A contractor who can perform a thorough inspection and document findings produces a valuable service (a moderate for typical inspection) and identifies remediation work the customer might not have considered. The customer pays for the inspection; the inspection often surfaces additional work.
When to perform
- Annual inspection (per customer preference)
- Real estate transaction (often required)
- After major weather event (heavy snow, wind)
- Customer reports concern (squeak, movement, sag)
- After other work nearby (landscape, addition)
- Insurance underwriting
What to inspect
A thorough inspection covers:
- Ledger attachment to house
- Joist structure
- Beam and post structure
- Footings
- Decking surface
- Railings and guards
- Stairs
- Fasteners overall
- Code compliance overall
Inspection procedure
Step 1: Pre-inspection conversation
- Talk with the customer about concerns
- Note any specific issues they want addressed
- Note the deck's age and history
- Note any prior repairs or modifications
Step 2: Visual inspection from underneath
If the deck has access underneath:
- Walk underneath the deck
- Inspect ledger attachment (look for fasteners, flashing)
- Inspect joists for rot, splits, sagging
- Inspect joist hangers (proper installation, all nails)
- Inspect beams for spans appropriate to size
- Inspect posts for plumb and condition
- Inspect footings (visible?)
- Look for visible structural issues
For decks without access underneath:
- Note this limitation
- Visual inspection from edge and from above where possible
Step 3: Inspect ledger attachment
The single most-important inspection point:
- Verify ledger is bolted (not nailed)
- Verify fastener spacing (16 inch on center typical)
- Verify fastener type (1/2 inch lag screws or through-bolts)
- Verify flashing is in place
- Look for evidence of water damage behind ledger
- Look for separation between ledger and house
Step 4: Inspect joists
For each joist:
- Visible rot (probe with awl in suspected areas)
- Splits or cracks
- Visible sag (sight along the length)
- End bearing on joist hanger
- Joist hanger condition (all nails, no corrosion)
Step 5: Inspect beams
For each beam:
- Span appropriate to size and load
- Splice locations (if any)
- Beam-to-post connection
- Visible rot or damage
Step 6: Inspect posts
For each post:
- Plumb (use level)
- Connection to footing (visible at base)
- Connection to beam (top)
- Visible rot, especially at base
Step 7: Inspect footings
For each footing:
- Visible above grade
- Cracked or settling
- Post base hardware in place
- Footing diameter appears adequate
Step 8: Inspect decking surface
Walk the deck surface:
- Boards firmly attached
- No loose boards
- No splinters or sharp edges
- No visible rot or damage
- Consistent gap between boards
- Surface drains properly
Step 9: Inspect railings
For each railing section:
- Height (measure; should be 36 inches minimum)
- Picket spacing (4 inch sphere test)
- Post anchoring (test by pushing; should be solid)
- Bottom rail to deck gap (should be less than 4 inches)
- Top rail integrity (push on rail; should hold 200 lb test)
Step 10: Inspect stairs
For each set of stairs:
- Riser heights consistent
- Tread depth consistent (10 inch minimum)
- Stringer attachment to deck
- Stringer attachment at bottom
- Handrail present (for 4+ risers)
- Handrail grippable
- Lighting (if low light)
Step 11: Inspect fasteners
- Spot-check various fasteners
- Visible corrosion (especially below deck level)
- Loose fasteners
- Missing fasteners
Step 12: Code compliance review
Compare findings against current IRC:
- Ledger fastener type and spacing (R507.9)
- Joist hangers (R507.6)
- Beam-to-post connection (R507.7)
- Footing depth (R401.3)
- Railing height (R312)
- Stair construction (R311)
Findings categories
Immediate safety concerns
Conditions that require immediate action:
- Failed ledger attachment (deck could collapse)
- Severely rotted structural members
- Loose railings
- Inadequate fasteners on critical connections
- Stair issues that could cause falls
These are reported as "immediate" with clear urgency.
Code violations (not immediately dangerous)
- Picket spacing slightly over 4 inches
- Bottom rail slightly over 4 inches
- Inadequate flashing
- Smaller code issues
These are reported as "should be addressed".
Maintenance items
- Surface refinishing needed
- Some loose boards
- Cosmetic damage
- Aged but functional fasteners
These are reported as "consider for ongoing maintenance".
Monitor items
- Slight settlement
- Minor cracking
- Adequate but aged components
These are reported as "monitor at next inspection".
Report writing
A complete inspection report includes:
Header
- Property address
- Date of inspection
- Inspector name and credentials
- Customer / client
Deck description
- Approximate size
- Material
- Estimated age
- Notable features
Findings by category
For each finding:
- Description
- Location
- Photograph
- Severity (immediate, near-term, monitor)
- Recommended action
- Estimated cost (if appropriate)
Recommendations
- Immediate actions
- Near-term actions (within 1-2 years)
- Monitoring schedule
- Annual inspection recommendation
Limitations
- Areas not inspected and why
- Conditions that limited inspection
Inspector certification
- Inspector name, signature, date
- Statement that report represents conditions at time of inspection
Common deck issues found
| Issue | Frequency | Action |
|---|---|---|
| Ledger nailed (not bolted) | Very high in pre-2009 decks | Recommend re-attach with bolts and flashing |
| Missing or failed flashing | High | Install proper flashing |
| Picket spacing > 4 inch | Common in older decks | Replace with closer spacing or add rail |
| Posts loose | Common | Add hardware or rebuild post |
| Joist rot | Common in old decks | Repair or replace joists |
| Beam undersized | Common | Reinforce or replace beam |
| Footing settling | Common | Stabilize or replace |
| Corroded fasteners | Common | Replace fasteners |
| Surface decking decay | Universal in older PT decks | Replace damaged boards |
Common inspection mistakes
Skipping the underdeck inspection
The most important findings (ledger, joists, beams, footings) are below the deck. Skipping this misses major issues.
References
- IRC R312 (Guards).
- IRC R311 (Stairs).
- IRC R401 (Footings).
- IRC R507 (Decks).
- IRC R314 (Smoke alarms; doesn't apply but is related to inspection).
- North American Deck and Railing Association (NADRA) inspection standards.
- Manufacturer literature: Simpson Strong-Tie, USP.
- Manuall internal: Deck Building Ledger Board Attachment Per IRC, Deck Building Joist Hanger Selection, Deck Building Railing Height Code.