Reverse Osmosis System Installation SOP

Purpose

Standardize installation of residential RO systems (kitchen drinking-water grade). Quality install determines years of trouble-free pure water; cut corners create leaks + low pressure.

Scope

Under-sink point-of-use (POU) RO systems. Excludes whole-house RO, commercial systems.

Prerequisites

  • RO system (3-5 stage typical)
  • Tools: drill, hole saw, wrench, tubing cutter
  • Standard install kit (faucet, fitting, drain saddle)
  • 2-3 hours per installation
  • Cold water supply + drain accessible under sink
  • Sometimes second hole in countertop needed for faucet

Procedure

Step 1: Site assessment

  1. Verify cold water supply under sink (RO needs cold only)
  2. Check supply pressure (40-100 PSI optimal; needs boost above 65 PSI for some membranes)
  3. Locate space for RO unit (typically under-sink)
  4. Verify drain accessibility for saddle
  5. Verify counter space for faucet (or existing faucet hole)

Step 2: Shut off water + drain

  1. Close cold water valve under sink
  2. Open existing faucet to relieve pressure
  3. Have towel/bucket for residual water

Step 3: Mount RO unit

  1. Mount unit to side wall of cabinet
  2. Use provided brackets
  3. Level + secure
  4. Allow access to filter housings for future change

Step 4: Install faucet

  1. If hole exists: position faucet, tighten from below
  2. If new hole: drill in countertop (1-1/4" hole typical)
  3. Connect supply tubing to faucet

Step 5: Connect to cold supply

  1. Use saddle valve (tap into existing supply) OR T-fitting
  2. T-fitting preferred (better reliability)
  3. Connect supply tubing to RO inlet

Step 6: Connect drain

  1. Install drain saddle on drain line
  2. Drill access hole
  3. Connect drain tubing from RO to drain saddle
  4. Maintain air gap (some jurisdictions require)

Step 7: Install tubing + tank

  1. Connect tank to RO output (storage tank holds pressurized water)
  2. Tank stands upright; air-pressurized

Step 8: Flush + test

  1. Open cold water supply
  2. Allow RO to flush for 1-2 hours (clears membrane preservative)
  3. Drain initial water (some manufacturers specify 2 tank-fills)
  4. Final water test: TDS meter shows reduced TDS (typical 90-95% reduction)

Step 9: Customer briefing

  1. Show faucet operation
  2. Explain tank refill time (slow; 1-2 hours after major use)
  3. Filter replacement schedule (varies by stage):
    • Pre-filter: every 6 months
    • Carbon filter: every 6-12 months
    • Membrane: every 2-3 years
  4. Tank pressure check (annual)
  5. Provide manuals + log

Acceptance criteria

  • All connections leak-free
  • TDS test shows 90-95% reduction
  • Water flow at faucet (slow but steady)
  • Customer signoff

Common pitfalls

  • Saddle valve corrosion: cheap saddles fail; prefer T-fitting
  • Drain saddle improper: leaks under sink
  • Wrong tubing connections: kinks restrict flow
  • No air gap on drain: code violation in some jurisdictions
  • Tank pressure low: slow refill (pressurize 7-10 PSI when empty)
  • Membrane not flushed: chlorine + preservative in first water

TDS reduction expectations

TDS in TDS out (5-stage RO)
50 ppm < 5 ppm
200 ppm < 20 ppm
500 ppm < 50 ppm
1,000 ppm < 100 ppm

If TDS reduction < 80%, troubleshoot.

Service intervals

Component Replacement
Pre-filter (sediment) 6 months
Activated carbon 6-12 months
RO membrane 2-3 years
Post-filter (carbon/taste) 12 months
Storage tank pre-charge Check annually

References

  • WQA RO standards
  • Manufacturer installation manuals
  • NSF 58 (RO certification standard)
  • Manuall internal: How to Balance Pool Water Chemistry, Water Filtration Technologies Reference