Key Blanks + Duplication Reference
Overview
Key duplication is a daily locksmith service. Understanding blank types, cutting techniques, + restricted-key policies is foundational.
Key blank anatomy
- Head / bow: end held by user (often plastic-coated)
- Shoulder: stops key at correct depth in lock
- Blade: portion inserted into lock
- Bittings: cuts on the blade (where the keyway pins rest)
- Tip: end of blade (sometimes pointed; sometimes flat)
- Keyway profile: cross-section of blade (matches the lock's keyway groove)
Key blank identification
Identifying a key requires matching:
- Keyway profile (cross-section): each manufacturer's keyway is unique
- Length: blade length matches the lock
- Bow shape: aesthetic, sometimes branded
A locksmith reads:
- Code stamped on key (some manufacturers stamp blank ID)
- Bow shape + profile: experienced locksmith identifies visually
- Lock manufacturer: customer often knows
Common blanks:
- KW1 (Kwikset): most common residential
- KW10 (Kwikset SmartKey): more recent Kwikset
- SC1 (Schlage): standard Schlage
- SC4 (Schlage Primus): restricted Schlage
- WE1 (Weiser): Weiser brand
- Y1 (Yale): standard Yale
- M1 (Master Lock): padlock standard
Duplication methods
Method 1: Mechanical key duplicator
The traditional machine:
- Insert original key + matching blank
- Tracer follows bittings of original
- Cutter cuts matching bittings into blank
- Inspect, deburr, smooth edges
- Test in customer's lock if possible
Process time: 1-2 minutes per key.
Accuracy: ±0.001" achievable with quality machine; ±0.005" common.
Cost: machine.
Method 2: Code cutting
For keys where you have the code (no original key):
- Code is the depth at each pin position (5-6 numbers)
- Code cutter machines: pre-program the code; cuts directly into blank
- Used when:
- Original key lost
- High-security with code on file
- Customer wants spare without showing original
Cost: machine.
Method 3: Impression
Older + specialty technique:
- Insert blank into lock
- Apply torque (binding pressure)
- File marks where pins bind
- File bittings progressively until lock opens
- Slow, specialty skill
Used for: high-security locks without code, custom situations.
Method 4: Decoding (advanced)
For some lock types, decoding the lock reveals the bitting:
- Specific lock manufacturers' locks decode-able
- Service code reads pin positions
- Cut blank to decoded specifications
Specialty + manufacturer-dependent.
Restricted vs unrestricted keys
Unrestricted (most residential):
- Blank widely available at hardware stores, big-box
- Anyone can buy + duplicate
- Convenient + cheap
- Low security: anyone can copy
Restricted (high-security):
- Blanks only available from licensed locksmiths
- Lock owner must authorize duplicates (often in writing)
- Manufacturer tracks all blanks sold
- Examples: Medeco, Mul-T-Lock, Schlage Primus, BiLock
- More secure: prevents unauthorized duplication
For customers with security concerns: upgrade to restricted system.
Patent + manufacturer protection
- Patent-restricted: protected by patent; manufacturer controls
- Trademark-restricted: blank shape trademarked
- Code-restricted: locks coded; blanks tracked by code
Most restricted systems combine multiple methods.
Common duplication issues
Wrong blank:
- Bow shape similar but profile slightly different
- Key inserts but won't turn (or only partially)
- Solution: identify correct blank; recut
Bittings too deep:
- Pin doesn't reach shear line
- Lock won't operate
- Solution: recut with proper depth
Bittings too shallow:
- Pin pushed too high
- Lock won't operate
- Solution: recut with proper depth
Worn bittings (smooth edge):
- Modern keys should have sharp bittings
- Worn key may not push pins correctly
- Solution: cut new key from blank using original as template (NOT a recut of worn key)
Cost considerations
For locksmith business:
- Blanks: each (standard);+ (restricted)
- Markup: typical 200-500% on duplication
- Customer pays: for standard duplicate; for restricted
- Wholesale machine investment:
- High-volume can be a profit center
For customer:
- Standard duplicate:
- Master / "high security" but unrestricted:
- Restricted (Medeco, Mul-T-Lock, Primus):
- Code cutting from scratch (no original):
Restricted-key system business model
For premium customers:
- Customer enrolls property in restricted system
- Authorization form on file at locksmith
- Each key cut requires customer authorization
- Audit trail of who has keys
- Premium upgrade for security-conscious customers
Locksmith collects ongoing revenue:
- Initial system install:
- Each key cut:
- Annual master key changes (optional):
ANSI / BHMA key designations
- A: highest pick resistance
- B: mid pick resistance
- C: standard pick resistance
- D: lowest
Higher level = more secure (anti-pick + anti-bump features).
Specialty key types
Bump-resistant keys: additional bittings to defeat bumping; require precise duplication.
Magnetic keys: small magnets in bow; lock detects via reed switch; expensive.
Electronic keys: RFID, transponder, contactless; common in automotive + commercial.
Smart keys: physical bow + electronic chip; emerging high-end.
Key blank inventory for a locksmith
Standard residential stock:
- KW1 (Kwikset): bulk
- SC1 (Schlage): bulk
- KW10 (Kwikset SmartKey): standard
- Y1 (Yale): standard
- M1 (Master Lock): standard
- 10-15 other common blanks
Specialty stock (high-volume locksmith):
- 100+ blank profiles
- Restricted system blanks (after enrollment)
- Automotive blanks
- Padlock blanks
Key wear over time
- Standard residential: 5-10 years before noticeable wear
- High-use (commercial, daily): 2-5 years
- Symptoms: harder to insert, harder to turn, dull bittings visible
When customer complains about key issues, check wear first.
Master key systems (residential)
For larger residential properties:
- Single key: all locks open with one key (master-keyed)
- Master + sub-master: primary key + secondary keys
- Top master: opens everything; submasters open subsets
Customer benefits:
- One key for entire property
- Hand out limited-access keys to staff/visitors
Setup cost:
- Initial rekey of all locks: setup +
- New master key blanks per lock: each
- Documentation: handed to customer for future maintenance
When to recommend restricted key system
- Customer concerned about ex-employees / past tenants
- Property management with rotating tenants
- High-value contents
- Commercial-grade security desired
- Customer willing to pay premium
The single biggest residential security upgrade most customers don't know about: A RESTRICTED-KEY SYSTEM. Standard Kwikset/Schlage keys can be duplicated by ANYONE at the hardware store. Customer doesn't realize their cleaning service, ex-tenant, contractor could've copied the key without their knowledge. For homes with valuables OR concerns, to retrofit a restricted-key system gives them peace of mind they didn't realize they were missing.
References
- ALOA standards
- Manufacturer technical specs (Medeco, Mul-T-Lock, Schlage Primus)
- Manuall internal: Lock Types + Mechanisms Reference, Rekey + Lock Change SOP